EMERSON Product|English

FISHER Type 92S

FISHER Type 92S

Type 92S self-powered control valves are piston actuated for high cycle steam service.Type 92S control valves and pilot use lapped seating surfaces that have been proven to minimize seat leakage.Types 6492H and 6492L pilots have bellows sealed stems to eliminate stem guide friction. The steel and stainless steel Type 92S control valves are available with a set point range of up to 250 psig / 17,2 bar and a maximum temperature of 650°F / 343°C.

Specifications

Pressure Registration

External

Maximum Temperature

Cast Iron Body:406°F / 208°C | Steel Body: 500°F / 260°C | Optional High-Temperature Steel or Stainless Steel Body: 650°F / 343°C

Body Sizes

NPS 1 / 1.5 / 2 / 2.5 / 3 / 4 / 6x4 | DN 25 / 40 / 50 / 65 / 80 / 100 / 150x100

End Connections

NPT / CL125FF / CL150RF / CL250RF / CL300RF / CL600RF

Maximum Inlet Pressure

Cast Iron: 250 PSIG / 17.2 bar | Steel: 300 PSIG / 20.7 bar | Or body rating limit, whicever is lower

Maximum Outlet Pressure

250 PSIG / 17.2 bar

Spring Ranges

2 to 250 PSIG / 0.138 to 17.2 bar

Features

Noise Reduction Capability without Decrease in Capacity

Good Shutoff for Low Downstream Buildup

Ease of Installation